Design Flexural and Sheer Strengths
LiteSteel Beam |
| ID |
wt per ft |
Design Flexural Strengths |
Design Shear Strengths |
|
|
|
|
|
| lb/ft |
kip ft |
kip ft |
kip ft |
kip |
kip |
| 1400LSB350-134 |
13.07 |
73.6 |
9.5 |
11.2 |
28.7 |
56.4 |
| 1400LSB350-118 |
11.59 |
63.5 |
9 |
10.1 |
19.9 |
50.4 |
| 1400LSB350-98 |
9.73 |
50.1 |
8.3 |
8.7 |
11.5 |
42.7 |
| 1200LSB350-134 |
12.17 |
60.5 |
8.8 |
11 |
28.7 |
56.4 |
| 1200LSB350-118 |
10.8 |
53.8 |
8.3 |
9.9 |
22.3 |
50.4 |
| 1200LSB350-98 |
9.07 |
42.7 |
7.6 |
8.5 |
14 |
42.7 |
| 1000LSB300-118 |
8.97 |
37.2 |
5.3 |
6.8 |
22.3 |
41.5 |
| 1000LSB300-98 |
7.54 |
31.4 |
4.9 |
5.8 |
15.5 |
35.3 |
| 1000LSB300-79 |
6.09 |
23.6 |
4.4 |
4.8 |
8.6 |
28.8 |
| 800LSB250-98 |
5.96 |
19.7 |
2.8 |
3.6 |
15.5 |
27.4 |
| 800LSB250-79 |
4.82 |
16.1 |
2.5 |
3 |
9.9 |
22.5 |
| 800LSB250-59 |
3.67 |
11.1 |
2.2 |
2.3 |
4.6 |
17.3 |
US 50 ksi steel
US Imperial (Launch 2008) |